Building code and structure

Footing / Foundation

Also called spread footing · slab foundation · stem wall

Subsurface supports that transfer building loads to the soil.

Applies to
  • Additions
  • Garages
  • Decks
  • Sheds
  • New buildings
Project example
A detached garage plan may require a thickened-edge slab, continuous frost footing, or engineered foundation depending on size, soil, climate, and local amendments.

Where this term shows up in permit work and how it affects the project

Foundation design determines excavation depth, reinforcement, anchoring, structural calculations, concrete inspections, and whether work can proceed before approval.

If this term appears in a form, plan comment, or local ordinance, start with the building permit guide, compare it against the zoning permit guide, then use the permit guide directory to find the right local path.

Try it on a sample

Set how deep the footing goes and watch where its bottom lands against a sample frost line.

GradeFrost line 42 in30 in
Frost depth30 in · 42 in minShort

12 in short. Soil above the frost line freezes and swells, and it can lift a footing that sits in it.

Sample frost depth. Each building department adopts its own, and some allow frost-protected shallow foundations or floating slabs for small sheds. Your Permit Workspace shows the number for your address.

Why it matters in a permit file

Footings spread building loads into soil, while the foundation transfers and supports the structure above. Permit documents must show a complete load path suited to local frost, soil, wind, geometry, and use—not merely label a line 'foundation.'

Where it appears in the permit process

  1. Design basis

    The designer establishes loads, soil assumptions, frost depth, bearing, foundation type, drainage, and the relationship to existing construction.

  2. Structural review

    Plans are checked for dimensions, depth, reinforcement, concrete or masonry, connections, anchors, slabs, and special engineering.

  3. Excavation and form inspection

    The AHJ may inspect soil, depth, width, reinforcement, forms, utilities, and setbacks before concrete is placed.

  4. Foundation completion

    Waterproofing, drainage, backfill, anchors, slab preparation, and as-built location may be verified before framing proceeds.

What you may need

  • Foundation plan and dimensioned sections
  • Design loads, frost depth, soil-bearing assumption, and material strengths
  • Reinforcement, anchor, slab, drainage, and waterproofing details
  • Geotechnical report or structural calculations when required
  • Existing-foundation connection details for additions

Where to get it or verify it

  • Use the AHJ's adopted code, climate criteria, local amendments, and standard foundation details.
  • Use a structural engineer or geotechnical professional when spans, loads, soils, slopes, retaining conditions, or existing structures fall outside prescriptive design.
  • Get proprietary anchor, form, and foundation-system documentation from the manufacturer.

Common mistakes that create comments or delays

  • Submitting a floor plan without a matching foundation plan
  • Using a generic detail that conflicts with local frost depth or the actual building
  • Pouring concrete before the required inspection
  • Changing building dimensions or post locations without updating the load path

What to do next

  1. Select a foundation approach that matches the building, site, and local criteria.
  2. Coordinate every wall, post, opening, anchor, and utility penetration.
  3. Obtain required engineering and approval before excavation.
  4. Schedule inspections before concrete, backfill, slab, and concealment.

Apply the term

See what this means for a real project address.

Permitech connects permit language to the responsible office, project requirements, required documents, and filing sequence.